Type: | Insulated |
---|---|
Conductor Type: | Stranded |
Application: | Industrial |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
ITEM | 1P×24AWG(7/0.20T) | ||||
CONDUCTOR | Material | Tinned copper stranded | |||
Size | 7/0.20mm | ||||
O.D.(Ref) | 0.60mm | ||||
INSULATION | Material | PE | |||
Min.average thickness | 0.50mm | ||||
Min.thickness at any point | 0.40mm | ||||
O.D. | 1.80±0.10mm | ||||
CABLING | Filler | PP rope | |||
Material | AL-mylar(Foil facing out) | ||||
Assembly | 1P×24AWG(7/0.20T) | ||||
DRAIN WIRE | Material | Tinned copper | |||
Size | 7/0.20mm | ||||
BRAID | Material | Tinned copper | |||
Size | 0.10mm(Min.90%) | ||||
JACKET | Material | PVC | |||
Min.average thickness | 0.76mm | ||||
Min.thickness at any point | 0.61mm | ||||
O.D. | 5.90±0.25mm | ||||
ELECTRICAL CHARACTERISTICS | PHYSICAL PROPERTIES | ||||
Rated voltage:30V | Tensile strength: | ≥10.3MPa | |||
Rated temperature:-30~80ºC | Elongation: | ≥100% | |||
Max.DC conductor resistance(20ºC):94.2Ω/km | Aged condition: | 113±1ºC×168h | |||
Voltage withstand test:AC 0.5kV/1min | Percent of original tensile strength: | ≥70% | |||
Nom. Characteristic Impedance:120Ω | Percent of original elongation: | ≥65% | |||
Nominal Delay:1.6ns/ft | |||||
Nom. Attenuation:0.6 dB/100 ft. @ 1 MHz |