Type: | Insulated |
---|---|
Conductor Type: | Stranded |
Conductor Material: | Copper |
Still deciding? Get samples of US$ 50/Meter
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
SPECIFICATION | CABLE NAME | EV Cable | |||||
CABLE SPEC | 2C×80mm2+1C×25mm2+2C×4mm2+(3C×0.75mm2)(P2)+(7C×0.75mm2) | ||||||
RoHS Compliant | |||||||
Item | A : 2C×80mm2 | B : 1C×25mm2 | C : 1C×4mm2 | D:(3C×0.75mm2)(P2) | E:(7C×0.75mm2) | ||
CONDUCTOR | Material | Bared copper stranded | |||||
Size | 2580/0.20 ±0.008mm | 798/0.20 ±0.008mm | 224/0.15±0.008mm +10/1#Tinsel+1000D Kevlar |
40/0.15±0.008mm+ 10/0.19mmTinsel+200DKevlar |
40/0.15±0.008mm+ 10/0.19mmTinsel+200D Kevlar |
||
O.D.(Ref.) | 12.40±0.25mm | 7.00±0.20mm | 2.70±0.15mm | 1.40±0.10mm | 1.40±0.10mm | ||
INSULATION | Material | Thermoplastic(EF2585,85±3A) | |||||
Min. average thickness | 1.60mm | 1.20mm | 1.00mm | 0.50mm | 0.50mm | ||
Min.thickness at any point | 1.34mm | 0.98mm | 0.80mm | 0.35mm | 0.35mm | ||
O.D. | 15.60±0.40mm | 9.60±0.30mm | 4.70±0.20mm | 2.50±0.10mm | 2.50±0.10mm | ||
CABLING-1 | Filler | / | Cotton | Cotton | |||
Material | / | AL-mylar(facing out) | Non-woven | ||||
BRAID | Material | / | Tinned copper | / | |||
Size | / | 0.12mm,≥60% | / | ||||
In-JACKET | Material | / | TPE | TPE | |||
Min. average thickness | / | 0.60mm | 0.60mm | ||||
Min.thickness at any point | / | 0.42mm | 0.42mm | ||||
O.D. | / | 7.20±0.25mm | 9.70±0.25mm | ||||
CABLING | Filler | Strengthed PP rope | |||||
Material | Non-woven(≥25% overlapping) | ||||||
Assembly | 2C×80mm2+1C×25mm2+2C×4mm2+(3C×0.75mm2)(P2)+(7C×0.75mm2) | ||||||
JACKET | Material | TPU | |||||
Min. average thickness | 2.80mm | ||||||
Min.thickness at any point | 2.28mm | ||||||
O.D. | 38.00+0.6/-1.00mm |
ELECTRICAL CHARACTERISTICS | PHYSICAL PROPERTIES | ||||||
Rated voltage:DC 1000V | Tensile strength:≥20MPa | High temperature pressure test:≤50% | |||||
Rated temperature:Jacket -40~90ºC | Elongation:≥300% | Heat shock test:No crack | |||||
Insulation -40~125ºC | Aged condition:110±1ºC×168h | Compatibility test:GB/T 33594 | |||||
Max. conductor resistance(20ºC): | Percent of original tensile strength:≤±30% | Crush resistance test:GB/T 33594 | |||||
A:0.242Ω/km B:0.78Ω/km C:4.95Ω/km D&E:26Ω/km | Percent of original elongation:≤±30% | Curved around the test:GB/T 33594 | |||||
Insulation Voltage withstand(Core A&B,10m): | Flame test:GB/T 18380.12-2008 | Min. Bend radius:6*OD | |||||
AC 2.5kV/5min,leakage current ≤5mA | Artificial weathering test:GB/T 33594 | Abrasion resistance:≥2000times | |||||
Completed cable Voltage withstand(Core A to A&B,10m): | Low-temperature impact test :-40ºC×16H,No crack | Resistance against chemicals:GB/T 33594 | |||||
AC 3.5kV/15min,leakage current ≤5mA | Chemical stress acid: N-Oxal-acid alkaline solution, N-sodium hydroxide solution:GB/T 33594 | ||||||
Min. Insulation resistance(20ºC, Core A to A&B):500MΩ.km | Vehicle rolling:Requirements and test methods should be consistent with GB/T 20234.1-2015 7.21 |