Type: | Insulated |
---|---|
Conductor Type: | Stranded |
Application: | Industrial |
Still deciding? Get samples of US$ 1/Meter
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
ITEM | A:2P×22AWG | B:4C×22AWG | |||
CONDUCTOR | Material | Tinned copper stranded | |||
Size | 19/0.16±0.008mm | 19/0.16±0.008mm | |||
O.D.(Ref) | 0.80mm | 0.80mm | |||
INSULATION | Material | SR-PVC(105ºC) | SR-PVC(105ºC) | ||
Min.average thickness | 0.23mm | 0.23mm | |||
Min.thickness at any point | 0.18mm | 0.18mm | |||
O.D. | 1.30±0.05mm | 1.30±0.05mm | |||
TWISTED | O.D. | 2.60mm | / | ||
Pitch | 30±10mm | / | |||
CABLING | Filler | PP rope | |||
Material | Mylar | ||||
Assembly | 2P×22AWG+4C×22AWG | ||||
JACKET | Material | PVC | |||
Min.average thickness | 0.76mm | ||||
Min.thickness at any point | 0.61mm | ||||
O.D. | 6.25±0.20mm |
ELECTRICAL CHARACTERISTICS | PHYSICAL PROPERTIES | ||||
Rated voltage:300V | Tensile strength: | ≥10.3MPa | |||
Rated temperature:-40~80ºC | Elongation: | ≥100% | |||
Max. DC conductor resistance(20ºC):59.4Ω/km | Aged condition: | 113±1ºC×168h | |||
Voltage withstand test:AC 2.0kV/1min | Percent of original tensile strength: | ≥70% | |||
Min.Insulation resistance(20ºC):10MΩ.km | Percent of original elongation: | ≥65% | |||
Flame test: | VW-1 |