Type: | Insulated |
---|---|
Conductor Type: | Stranded |
Application: | Industrial |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
ITEM | 4P×22AWG(43/0.10T) | ||||
CONDUCTOR | Material | Tinned copper stranded | |||
Size | 43/0.10±0.008mm | ||||
O.D.(Ref) | 0.76mm | ||||
INSULATION | Material | PE | |||
Min.average thickness | 0.23mm | ||||
Min.thickness at any point | 0.18mm | ||||
O.D. | 1.30±0.05mm | ||||
TWISTED | O.D.(Ref) | 2.60mm | |||
CABLING | Filler | Optional | |||
Assembly | 4P×22AWG(43/0.10T) | ||||
Material | Non-woven | ||||
Material | Al-mylar(facing out) | ||||
Assembly | 4P×22AWG(43/0.10T)+WA | ||||
BRAID | Material | Tinned copper | |||
Size | 0.12mm,85% Min. | ||||
JACKET | Material | PU Ether | |||
Min.average thickness | 0.85mm | ||||
Min.thickness at any point | 0.68mm | ||||
O.D. | 8.80±0.25mm | ||||
ELECTRICAL CHARACTERISTICS | PHYSICAL PROPERTIES | ||||
Rated voltage:300V | Tensile strength: | ≥10.3MPa | |||
Rated temperature:-40~80ºC | Elongation: | ≥100% | |||
Max. DC conductor resistance(at 20ºC):59.4Ω/km | Aged condition: | 113±1ºC×168h | |||
Voltage withstand test:AC 2.0kV/1min | Percent of original tensile strength: | ≥70% | |||
Percent of original elongation: | ≥65% | ||||
Bending Test:no load,30times/min,bend radius:30mm,angle±90°,times≥150000 | |||||
Flame test:VW-1&IEC 60332-1-2 |